I need at least 1 anchor bolt for each 8′ of wall section. Anchor bolts have to be installed properly for them to be effective. The size and location of structural elements, reinforcement and anchors. The magnitude and location of prestressing forces. Anchorage length of reinforcement and location and length of lap splices. Type and location of mechanical and welded splices of reinforcement. Inspectors may use their own report forms as long as all of the required information is provided therein. Are you using the strongest anchor bolts?

This does not happen with headed anchors. This method of traveling shall not be permitted, however, if the sill or ledge is not continuous with at least 6 inches in front of the mullions or if each window unit is not readily accessible.


Learn how to install different types of anchors in concrete and brick, using a hammer drill. Strike anchor, concrete screws, drive …Riverside California – California Masonry Anchor Bolt

California  Bolt Anchor Bolts Needed Spacing. Stainless Steel Load Grout Anchor

How many anchor bolts are needed (spacing)?

How many anchor bolts are needed (spacing)? Depending on this, the occurrence of low cycle fatigue due to accumulated plastic steel strains may govern performance. Is your question directed at a location in these areas?

Is the question directed at a “high wind” area?

When the anchor bolts, in your area, are installed, how are they being installed?

When building in high wind areas, extra reinforcement measures are required. Details and location of contraction or isolation joints specified for plain concrete. Stressing sequence for post-tensioning tendons. Newer homes generally have anchor bolts or straps. As the torque is applied the plastic expands the sleeve against the sides of the hole acting as expansion force. A screw is inserted into the base material via a gas actuated gas gun. Not all anchor bolts are created equal – not even close. Read on to see how you may be able to achieve better performance with no increase in material or construction costs. In particular, the bent region of bent-bar anchors can be brittle. Pullout capacity is calculated assuming that no special measures are taken to remove oil from the anchor shank. Headed anchors can have more than 4 times the capacity of otherwise identical bent-bar anchors. Also provide socket shoulder bolts, slotted round head stover bolts, carriage bolts, hex tap bolts and stainless steel carriage bolts. An installed anchor shall not be used for any purpose other than attachment of window cleaner’s belt terminals. When the distance is from 6 feet to 8 feet wide, anchors are required unless there is a railing or parapet at least 2 feet high.

I haven”t been able to get on here. Short pieces of material often appear between garage doors or in short walls. If you are saying that he wants (2) anchor bolts at the end of each plate, that is wrong. That is very much what we have when both sill plates are lapped and fastened together per schedule. The bolts are required to be embedded a minimum 7″ into the concrete, so standard length bolts aren”t long enough. It is a structural continuity matter and that sill plates shall act as much as possible a unified structure. If a plate section is only bolted only on one end then the loose end can essentially swivel out of alignment. I think it is good reasoning for having secured sill plates. Why do you usually use double sill plates?

The unidirectional 12 mm (0.47 in.) steel reinforcing bars resulted in a reinforcement ratio perpendicular to the cracks of 0.8 %. Then the wedges were removed to allow the crack to close, and the anchors were installed according to the manufacturer’s published installation instructions with the specified embedment depth hef.

All tests were performed on single anchors with large edge distances. The cracks were opened by the specified crack width of 0.5 mm or 0.8 mm (0.02 in. Mechanical anchors were tested under unconfined conditions with a clear distance between the beams of 4hef. The concrete slab was braced against the strong floor and frontal supports acted as horizontal bearing. These residual capacity tests as well as the reference tests were run displacement-controlled and the ultimate load was reached within 1 min to 3 min (quasi-static).

Sufficient steel strength and the specific embedment depth prevented steel failure.

Shop Anchor Bolts at Lowes

California Masonry Anchor Bolt
Sample load-displacement curves of load controlled cyclic tension load tests on anchors as well as corresponding mean curve of monotonic reference tests (0.5 mm and 0.8 mm (0.02 in.

The concentrated load transfer at the anchor base by mechanical interlock allowed a deep concrete cone to develop at failure. Expansion anchors transfer the tension loads by friction between anchor body and expansion element, and expansion element and concrete. Bonded anchors transfer tension loads via the adhesive mortar into the concrete. It is known that high load amplitudes, relative to the capacity, or large numbers of cycles potentially damage the anchor steel or the concrete base material and cause high cycle fatigue failure36, but here the number of load cycles and load amplitudes of the tested load protocol were too moderate to result in any material damage.

For the anchor products tested in 0.5 mm and 0.8 mm (0.02 in. This result is in line with earlier studies18. The effect of increased crack widths on the displacement behavior depended on the anchor type. Taking the large scatter of the displacements at ultimate load, a clear trend for the displacements for crack widths increased from 0.5 mm (0.02 in.) to 0.8 mm (0.03 in.) cannot be inferred for the tested anchors.

All anchors failed by steel rupture of the anchor either during load cycling or in the subsequent residual load capacity test. The anchors were located far from edges to exclude concrete edge failure and deep enough to exclude pry-out failure. The anchor bolt and sleeve, which was installed flush with the fixture, ruptured at concrete surface. The scatter of the displacements was relatively small with a maximum of variation v of 25 %. Despite the prevalent steel failure mode, the energy dissipation was small, though larger than under tensile load cycling. Furthermore, anchors experience highly-localized plastic deformation along the shear plane under shear loads40. The stiff sleeve attracts more shear load than the bolt, which can move within the sleeve, and is therefore subjected to higher shear load amplitudes causing low cycle fatigue failure.

Since the above discussed load controlled tests proved that alternating shear cycling is more critical than pulsed one direction tension cycling, only cyclic shear tests are reported herein.

Particular attention had to be paid to the annular gap around the anchors as uneven gaps result in asymmetric load-displacement curves. In contrast to load controlled tests with increasing displacements within a load step, the displacement controlled tests showed decreasing loads within a displacement step.

The mean peak load is approximately equivalent to the residual strength determined in the other displacement controlled tests. For the tested load regime, the number of cycles and the load levels were sufficiently low to prevent damage in the anchor or concrete during tension load cycling.

In all residual capacity tests, concrete-related failure modes occurred (concrete breakout or pullout). Tests in larger cracks consistently resulted in reduced load capacities. This behavior was particularly prevalent for anchors with sleeves in the shear plane presumably owing to their larger monotonic capacities, which dictates a higher load cycling demand, and uneven distribution of the applied shear load between the anchor sleeve and bolt.

Standard method of cyclic load test for anchors in concrete or grouted masonry. Survey and characterization of floor and wall mounted mechanical and electrical equipment in buildings. An attic space may be considered a story if it has been remodeled for use as a room. October 3, 1955, shall be installed while the wall is under construction and shall be shaped to build into the joints between masonry units.

At least two machine screws or bolts of 3/8-inch diameter stainless steel or equivalent passing through the frame and a steel reinforcing plate 3/8-inch thick that extends not less than 5 inches above the top bolt hole, placed on the inside of the frame and secured by means of nuts and lock washers.

Bolts used to attach anchor fastenings shall be secured by means of nuts tightened to the torque specified by the bolt manufacturer or other equivalent means.

At least two machine screws or bolts of 3/8-inch diameter stainless steel or equivalent passing through the frame and secured by means of nuts and lock washers.

When anchors are attached to hollow or solid aluminum frames, the reinforcing plate shall be coated or protected so as to minimize electrolytic action between unlike metals.

The use of expansion shield anchors is prohibited. Regarding steel to concrete connections, some examples consist in collision of vehicle on barriers connected to concrete base and explosions. For instance, seismic pull-out action on anchor can have 0.03 seconds of rise time. Adhesion between polymers and concrete. Fracture mechanics of concrete structures: 281–299. Building code requirements for structural concrete. Sizes of bolts include 0.188 in., 0.250 in., & 0.313 in. Also carry cabinet hardware, bath hardware, cargo hardware, and lock sets. Cathodic protection equipment also available, as well as flange insulation, modular seals, and casing spacers. Suitable for water and waste water industries. Assorted bolts, bolts with drilled holes, kingpin bolts, fork to frame bolts & zinc plated hex head bolts are also available. Materials include steel in plain finish. Old mortar shall be cleaned from the unit before reuse. Unless structural support and anchorage are provided to resist the overturning moment, the center of gravity of projecting masonry or molded cornices shall lie within the middle one-third of the supporting wall.

Grouted masonry shall be constructed in such a manner that all elements of the masonry act together as a structural element. Prior to grouting, the grout space shall be clean so that all spaces to be filled with grout do not contain mortar projections greater than 1/4 inch (6.4 mm), mortar droppings and other foreign material.

Reinforced grouted masonry is that form of construction made with clay or shale brick or made with solid concrete building brick in which interior joints of masonry are filled by pouring grout around reinforcement therein as the work progresses.

All reinforcement and wire ties shall be embedded in the grout. Where high-lift grouting is used, the method shall be subject to the approval of the enforcement agency. Kinks, water drips, or deformations shall not be permitted in the ties. Grout shall be consolidated by mechanical vibration only, and shall be reconsolidated after excess moisture has been absorbed, but before plasticity is lost. Reinforced hollow-unit masonry is that type of construction made with hollow-masonry units in which cells are continuously filled with grout, and in which reinforcement is embedded.

The depth of the bond beam channel below the top of the unit shall be a minimum of 11/2 inches (38 mm) and the width shall be 3 inches (76 mm) minimum.

Units shall be laid a maximum of 4 feet (1220 mm) before grouting. Horizontal reinforcement shall be fully embedded in grout in an uninterrupted pour. Where high-lift grouting is used, the method shall be approved by the enforcement agency. Alternatively, if the course at the bottom of the pour is constructed entirely of inverted double open-end bond beam units, cleanout openings need only be provided for access to every reinforced cell at the bottom of each pour of grout.

An approved admixture that reduces early water loss and produces an expansive action shall be used in the grout. Not less than two cores shall be taken from each building for each 5, 000 square feet (465 m2) of the masonry wall area or fraction thereof.

Core samples shall not be soaked before testing. Neither the horizontal nor the vertical reinforcement shall be less than one third of the total. Vertical wall reinforcement shall have dowels of equal size and equal matched spacing in all footings. Ties shall be at least 3/8 inch (10 mm) diameter and shall be embedded in grout. Bent bar anchor bolts shall not be allowed. Continuously at structurally connected roof and floor levels and at the top of walls; 2. Table 1908.2 are for the edge distance and spacing specified.


Concrete Anchors

Concrete anchors are a heavy duty anchor for fixing objects to masonry surfaces. Here we use a thru bolt to demonstrate how to …