Cracks In Veneer Walls. Weep Holes Veneer Mortar Joint Masonry Veneer Lintel Expansion Joint Brick Veneer
In several places, the brick veneer has moved, cracking and causing misalignment as pictured. This is on the basement level, on the walkout side of the basement. Assuming the repairs have worked and the veneer in fact is no longer moving, what are my options for fixing the gap? It also provides thermal insulation, waterproofing and drainage management to the building structure.
Although repointing may be considered “minor” maintenance because no serious damage may be visible, it is a very important part of the maintenance plan for your building walls.

These usually occur when there is external or internal stress on the wall. If the pieces are large enough to glue back on, set these aside. For example, if you add three shovels sand, mix this with one shovel of mortar in a large bucket.  The cracks look like they have previously been filled. Brick veneer remains one of the most popular wall coverings in many markets, especially in higher end homes. It’s important to distinguish brick veneer from structural brick. European countries until mid-twentieth century the façadewalls were characterized by single leaf walls, built with stone, brick oradobe [2] ensuring the global stability of the buildings.

However, the maintenance costs and the need to avoid or reduce problems withhumidity and thermal bridges led to the development of brick veneerwalls [2].

The ice damming needs to be corrected before repairs to the brick are made. I looked at my neighbor’s house and noticed that he had a couple stair step cracks in his brick. Didn’t see any interior damage to wall or ceilings and all doors to this area closed without rub/stick.
It simply cannot stretch to any appreciable degree without cracking to relieve stress and strain.


If you have a brick home, then you may struggle with cracks on the outside of your home. You can easily repair small cracks with …Vertical Cracks in Masonry Veneer Wall. Help – Cracks In Masonry Veneer Walls

Cracks In Veneer Walls. Weep Holes Veneer Mortar Joint Masonry Veneer Lintel Expansion Joint Brick Veneer

As mentioned above, ignoring a bowed or cracked structural wall is a very serious mistake.  Treating efflorescence is not a simple task. Don’t carelessly apply off-the-shelf efflorescence treatments. Can ‘nook’ be used outside the saying ‘nook and cranny’?

Also, the roof on this house is older and probably towards the end of its life. Anyone can smear some schmutz on those cracks but it won’t solve the problem.  And the bricks with the cracks should be replaced?

I don’t see any brick expansion joints so mother nature was going to break the bricks where she wanted.  The bricks broke due to shear structural forces as they broke in a straight line.  I would look at the walls and see if they are bowing outward.  Bricks expand when they get wet because they are clay products.   I don’t see any flashing at the base of the wall which would be below the weep joints.   Water has no way of getting out from behind the brick. I would clean out the joints where the cracks are and place backer rod and sealant.  Weep holes need to be added or exposed/cleaned out.  Start analyzing real estate properties, we do the math for you.
These joints allow water to flow past the joint while still providing a decorative appearance. Any mortar joint that leaves a shelf for water to collect on the lower brick (raked and struck joints) is a potential water problem and should be reported.

Chimneys are especially prone to mortar and brick deterioration.
Speaking of chimneys, mortar that is exposed to sulfur and water can expand and cause the chimney to curve. Sulfation can occur in other brick structures that are exposed to frequent wetting and can be a reason for cracking and distortion of bricks and mortar.

Each horizontal row of bricks and mortar is a course. A wythe (also spelled withe) is a vertical wall of bricks one brick thick. Brick veneer is almost always one wythe thick. At least one wythe should separate flues in a chimney.
Bricks are installed with different sides exposed and in different orientations. Bricks are usually installed with their long side horizontal. Bricks installed with their long side vertical are soldiers (narrow side out) or sailors (wide side out). Soldiers and sailors are often used above windows and doors for decoration. Corbelled courses should use solid bricks, not bricks with holes. Sometimes you’ll see a thin coat of mortar to hide the holes where the bricks are corbelled. Lintels should be installed above openings such as windows, doors, and fireplaces. Lintels should also be installed when brick veneer is supported by framing.
At least 4 inches of each lintel above openings should be supported by the bricks on each side of the opening. Rusted lintels can expand enough to cause cracks in the mortar. You should report rusted lintels even if they haven’t caused cracking, yet.
Besides, we can’t usually see the lintel’s vertical section so there’s no way for us to know the lintel’s size. We can, however, look to see if the lintel is sagging. Brick veneer may be supported by framing, but not directly on framing. The bricks must be supported on a lintel. The lintel usually is not visible during the inspection because it is (or should be) concealed by flashing. A movement joint should be filled with a material like caulk that is more flexible than mortar. Movement joints are frequently omitted, so watch for them. Flashing and weep holes should be installed above and below windows, above doors, below the first brick course above finished grade, and at each floor level.

The flashing should extend to the brick veneer surface. Weep holes should be at least 3/16 inch in diameter and should be spaced at least every 32 inches. Flashing as described here is unusual in older construction; heck, it’s unusual in some newer construction. The risks of not having weep holes certainly deserve mention for older structures. The ideal counter-flashing would be embedded in the mortar. The counter-flashing may also be installed in a groove cut into the mortar and sealed with caulk or roofing cement. Kick out flashing should be installed where a sidewall extends past a roof.
Those small cracks in the mortar are the scary ones. You should certainly report their presence. Evaluation may be appropriate if the crack is wide enough to insert a dime.
Reporting cracks in brick veneer boils down to experience in your local market. Newer inspectors should ask more experienced inspectors for advice. Chapter meetings are an excellent place for this.
After all, how many building materials are featured in a children’s story?

If a brick is broken or cracked, it should be replaced to prevent moisture from seeping into your walls. Brick buildings, however, require routine maintenance. I have a damp feeling in the floor inside. Additionally, in cavity and veneer wallssubjected to lateral wind loads, the wall ties connecting the cavityleaves or the veneer to the backing system shall be capable ofdistributing the wind loads from the loaded external leaf to the internalleaf and from the veneer wall to the backing system, respectively.2.2.

Tie connection failures are often theresult of tie pull-out from poor mortar joints and/or too short tieembedment length into the mortar joint. European countries brought tolight vulnerabilities of masonry veneer walls. The hysteresis diagrams werecharacterized by pinching and asymmetry became pronounced forincreasing displacements. The predominant failure mode observed in the mono-tonic tension tests of nailed subassemblies was nail pull-out from thewood stud, which helped to explain why tie thickness had no effect onthe average tensile strength.

It is also important to assess the main parameters influencingthe local behaviour of the steel ties embedded both in brick veneers andbrick infill masonry walls.3.2.

When only brick veneer systems are tested, a reaction structure that is capable of providing the backup walls withadequate boundary conditions to be representative of a real situation iscritical.

Cracks In Masonry Veneer Walls
In the out-of-plane direction, thereaction structure is welded to two inclined trusses at each side of thewall and bolted to the table. Besides thebehaviour of the ties, it is important to evaluate the effect of the globalseismic behaviour of the buildings on the brick masonry veneer andunderstand the extent the masonry veneer can contribute for the globalseismic response.

Joint reinforcing in the mortar jointswas also considered. Borchelt [32] states that in-plane behaviour is controlled byshear capacity of each element of the masonry veneer system (masonryveneer, ties and backing wall). Thenumerical models were calibrated based on dynamic shaking tabletests. Nonlinear elasticspring supports were implemented along the base of the brick veneerwall panel, representing a rigid body rocking behaviour. Appropriate hysteretic models were consid-ered for the nonlinear truss elements simulating the ties. For an uncracked masonry veneer, the force distribution onthe ties was influenced by the flexibility of the backing walls and thewall boundary conditions.

The redistribution of forces depends alsoon the stiffness of the ties, being lower in case of stiffties. Zisi [39], which referred that the initial wall stiffness can increase between 41%and 60% if optimal installation practice of the ties was considered. Note that the part ofthe numerical analysis is focused on single panels where simplificationof the boundary conditions and of the mechanical behaviour of theresisting system is considered by adopting linear elastic materials.

It defines also limits for the lateral drifts to limit thedamage in the non-structural elements.5. Additionally, the interaction between the brick veneers andthe backing system has been also analysed based on shaking table testson buildings with brick veneers attached.

Brick “siding is not structural it is siding. Having stated that i also agree that cracks in masonry is almost normal and should be expected as long as the cracks are not active and/or have displacement.

This is a very short answer but any more will require a dissertation.
Shear cracks like that through all those bricks?

I have measured the crack and there is no crack that is part of the actual brick greater than 1/8 of an inch. It is difficult to know what is going on without more details. Masonry or frame construction?

Thank you all for the free knowledge. I do think the probability of enough water being blown in to cause a problem, is probably small. Live and learn, unfortunately the lesson can be expensive, hopefully not in this case.
Water could enter in the lower areas of the wall where the crack is not protected from the overhang of the roof.

You did not mention if there are any weep holes at the base of the brick which would allow water to exit should be be driven into the crack.

My initial response was regarding the crack being a structural concern.
I have never seen a structural engineer check out anything. Around here, 1971 may have a crawl space. Most likely brick veneer, not structure. All that adds up to, did they do it right from the start. With control joints there should absolutely be no cracking if it is done right. There is a vast amount of knowledge needed to determine what and why. There is no such thing as “normal” cracking. There is always a reason for the cracking. An 1/8th of an inch is a good crack. Are there similar cracks in the sheetrock inside the building?

Incidently, stair-stepped cracks in masonry or brick construction indicate poor mortar and/or inadequate reinforcement. The mortar should bond to the masonry, and any cracks that might occur should go through the blocks regardless of joint location, and not stair-step.

Some builders put expansion joints in wall, hoping the wall will move at the expansion joint. Building construction varies quite a bit by region. Settlement cracks in block often stair step-mortar is almost never as strong as the block.
Everyone either screws up and does not engineering. Or normal as in all the way from the engineering to the maintenance is totally inadequate. I see is a grading and drainage situation. There is always a reason and always a correction and a maintenance program that will keep it from happening again. Cause and affect and correction is what the client has to be taught. Install sprinklers around the perimeter that adds the same moisture level around the entire perimeter that can be watered. I am sure someone missed it in the past. They actually put piers based on the extreme measurement all across the front and several half way up each side with varying amounts of lift and the house just did not show it that much due to the lay out.

F weather, and it looks to me to have problems. Certainly you’re not going to see the builder re-do the whole wall. Below we provide two more photos of more serious brick veneer wall cracking – movement or separation from the building. It may be possible to repair this veneer wall using special fasteners.
Hairline cracks at the building corner might not be serious enough to leap into action.
Is the brick veneer facing properly supported?

Are there long brick veneer walls without expansion joints?

But a loose or even falling brick veneer – alone – is not the same level of risk as the potential collapse of an entire building!

I have seen many hairline and step cracks in brick exterior house walls.
I realize you can’t see the property in person and would not ask you to render any opinion for use in this argument. The “structural inspection” must be performed by a qualified expert, perhaps a structural or civil engineer who has specific experience and expertise with brick and brick veneer construction and veneer repairs at residential buildings.

For about 12 feet in the center of the wall.


Home Inspectors Nashville Discovers Repaired Cracks In Brick Veneer Wall

ultrasoundinspections.com Home Inspector Nashville writes: Repair cracks in brick mortar joints can be a sign of foundation …